4 Technical instructions
Mounting options
Al l robot examples in the catalog refer to floor mounted version. For more detai ls on wal l and cei l ing mounting please contact our technical department.
Floor mount
Wall mount
Ceiling mount
Fig. 26
Fig. 27
Fig. 28
Anchoring the Robot Transfer Unit
It is possible to anchor the system to the floor through the fixing holes, ei ther by inserting the different sizes of screws that will have to be anchored in steel bushings inserted into the cement or by using threaded bars with chemical anchor bolts inserted into the cement. Therefore, make sure that : If using steel bushings inserted into cement, the embedment length of the anchor screw must be at least 1.5 times the diameter. For correct ancho ring of the steel bushings into the cement, follow the directions provided by the bushing manufacturer:
■ For M10 screws: 10x1.5 = 15 mm embedment; ■ For M12 screws: 12x1.5 = 18 mm embedment; ■ For M16 screws: 16x1.5 = 24 mm embedment; ■ For M24 screws: 24x1.5 = 36 mm embedment.
If anchoring with threaded bars, make sure to insert the bar into the ce ment with a chemical anchor that is at least 9 times its diameter:
■ For M10 screws: 10x9 = 90 mm embedment; ■ For M12 screws: 12x9 = 108 mm embedment; ■ For M16 screws: 16x9 = 144 mm embedment; ■ For M24 screws: 24x9 = 216 mm embedment.